VULCAN-VULCAP ACCESSORIES VULCAN-VULCAP INFLATABLE MANDRELSVULCAN-VULCAP Inflatable Mandrels are constructed of a heat resistant rubber core and an outside high tensile heat resistant, pre-shrunk nylon cover for maximum service life. The Inflatable Mandrels are shaped to the inside of the tire. They are light weight, easy to use and come with a 400 hour pro-rata warranty. VULCAN-VULCAP Inflatable Mandrels are available in a variety of sizes. VULCAN-VULCAP MANDREL ADAPTORS
VULCAN-VULCAP INSIDE HEATPADS
AIR DIFFERENTIAL CONTROL is available as separate retrofit accessory or "built in" to new molds. The Air Differential Control automatically inflates inside mandrel and outside Airbags simultaneously maintaining differential of 12-15 lbs. higher pressure on the inside of the tire (pressure is typically 45 psi inside and 30 psi outside).
All VULCAN-VULCAP
Heatpads are built to
VULCAN-VULCAP OUTSIDE AIRBAGS
VULCAN-VULCAP BEAD FILLER PADS
VULCAN-VULCAP SIDE FILLER PADS
VULCAN-VULCAP REPLACEMENT PARTS
| ||||||||||||||||||||||
HEATPADS AND AIRBAGS FOR Vulcaflex® AND OTHER FLEXIBLE SYSTEMS
VULCAN-VULCAP now manufactures a full range of
Thermocouple Heatpads and Airbags for all Strap, Flexible, OTR and Truck Tire
Repair Systems. Our Heatpads are fully compatible with MONARCH, NATIONAL
or VULCAN systems. They are equipped with the proper plugs for each
system they are ordered for. These pads generally are more rugged than
pads manufactured by other companies and have a reputation for outlasting
others.
For certain applications, we do have L-shaped Heatpads that
conform to the shoulder of the tire to be repaired. These pads are better
than thin, flat pads as they are already contoured for the shoulder of the tire.
|
|
|
|
|
VV1213H
|
VV2217H
|
VV2519H
|
|
|
|
|
|
VV2210H
|
VV2215H |
VV6624H |
|
|
|
|
|
VV3132H
|
VV4224H |
VV4220H |
|
|
|
|
|
VV2626H
|
VV3015H |
VV2519H |
L-SHAPED HEATPADS FOR Vulcaflex® AND OTHER FLEXIBLE SYSTEMS
Unique to the Vulcaflex® trademark series of Heatpads which are also compatible with other flexible systems such as Monaflex and National, are our L-shaped Heatpads shown below. These L-shaped Heatpads are molded to shape to conform better to the tire when performing shoulder repairs. They have been developed by VULCAN-VULCAP technicians based on over 60 years of experience in the design and building of tire repair equipment.
|
|
|
|
|
VV180 LS Heated
|
VV180 LS Heated |
VV250LS Heated |
|
|
||
|
VV250LS Heated
|
||
|
All
VULCAN-VULCAP
Heatpads are built to
AIRBAGS FOR Vulcaflex® OTR AND OTHER FLEXIBLE SYSTEMS
|
||
|
|
|
|
|
VV2621FAB
|
VV3624FAB |
VV4824FAB |
|
|
|
|
|
VV4832FAB OTR Airbag 48" x 32"
|
VV5432FAB |
VV7532FAB OTR Airbag 75" x 32"
|
|
CYLINDRICAL AIRBAGS FOR Vulcaflex® OTR SYSTEMS Pictured below are various views of the latest results of VULCAN-VULCAP'S research and development in a continuous effort to improve our OTR repair systems. This is a large cylindrical Airbag constructed of heat resistant rubber core for OTR tire sizes 50/80-57 and up. VULCAN-VULCAP developed special techniques and molds to produce this very large Airbag. Due to the large air volume, this Airbag is being supplied with a triple wall high tensile heat resistant, pre-shrunk nylon cover to ensure safety and maximum service life.
|
||
![]() |
![]() |
![]() |
|
VV4447/32CAB In up right position
|
VV4447/32CAB In horizontal position |
VV4447/32CAB In side front position |
![]() |
|
|
|
VV4447/32CAB In side position
|
VV3842/37CAB Side view under test in section of OTR tire |
VV3842/37CAB End view under test in section of OTR tire |
|
|
|
|
VV3842/32CAB Deflated for shipment, Note: Once Cylindrical Airbags are inflated, they should always stay inflated under very light air pressure and not completely deflated as for shipment purposes only.
|
VV3842/32CAB In upright position |
VV3842/32CAB In horizontal position |
|
|
|
|
VV3336/32 In Vertical position |
VV3336/32 In Horizontal position |
VV2732/32 In Vertical position
|
|
|
|
|
VV2732/32 In Horizontal position
|
VV2732/32 In Side Horizontal position |
VV2427/32CAB In Vertical position |
|
|
|
|
VV2427/32CAB In Horizontal position
|
VV1518/24CAB In Horizontal position |
VV1518/24CAB In Vertical position, Close-up |
|
||
|
VV1518/24CAB Horizontal position held by straps |
All
VULCAN-VULCAP
Heatpads are built to
and
standards
and certified to
.
VULCAN–VULCAP
TREAD LUG FILLER BAGS
A
new and easy Method to protect Heatpads when
curing Repairs in OTR Tires
Taking the time to correctly fill in the voids of an OTR tire will extend the
life of your Heatpad.
When the lug voids of the tread design are not filled in properly, the Heatpad
is distorted when pushed into the voids by the pressure of the Airbag.
The Heating Element inside the Heatpad is then damaged and may cause the
Heatpad to overheat. This can
result in a fire starting in the tire.
In the case of strap type curing systems, it can also damage the thermocouple
sensor wires.
Solutions
There are a few different ways in which to fill in the
tread voids:
(1) Plaster of Paris - this is a good procedure to use but is very messy and time consuming.
(2) Aluminum foil - this is easy to use but very often not enough tin foil is used. The void looks like it has been filled but when air pressure is applied, the foil compresses into the tread void and the heatpad then becomes distorted.
(3) Other types of fillers - these are always messy.
The Best Solution
VULCAN-VULCAP’s
new Silica Sand filled Tread Lug Filler Bags
are the best alternative to the above.
§ The Silica Sand is very fine and allows the sandbags to take the shape of the tread void.
§ The Tread Lug Filler Bags come in sets of 20 bags in various sizes.
§ We realize that this may not cover all the different size Lug Void Configurations, therefore additional bags can be made to customer specifications.
Please note:
Heatpads that fail because Tread Voids are not filled in properly are not
covered under Warranty as the sharp Tread Edges destroy the Heating Elements!

Below are pictures of VULCAN-VULCAP Heatpads that were used and damaged beyond repair due to failure of using lug fillers. This damages the Heatpads unnecessarily and is not covered under warranty. It is very important to avoid this kind of costly mistake!
|
|
|
|
|
|
***
Another graphic example how a Heatpad was irreparably damaged and burnt out because the customer did not use lug fillers. You will note how the lugs are imbedded in the Heatpad, destroying and thus shorting out the heating elements completely.
|
|
|
|
|
|